Infrared Ear Thermometer

TH709LE

  • Delicate Storage Box with Probe Cover Fixer
  • Probe Cover for Hygiene
  • Probe Cover Detector
  • Worldwide Smallest Probe
  • Last Reading - Temperature Comparison
  • One Second Measurement
  • Temperature Awareness Signal
  • LED Backlight 
  • 25 memories
  • TH709LE
    Probe Cover
  • TH709LE
    1 Second Measurement
  • TH709LE
    Wordwide Smallest Probe
  • TH709LE
    Probe Cover Detector
  • TH709LE
    °C/°F Switch Mode
  • TH709LE
    Last Reading

Introduction

    • Temperature measureme range:  34~42.2°C (93.2~108°F)
    • Accuracy:  ±0.2°C (0.4°F) within 35~42°C (95~107.6°F), ±0.3°C (0.5°F) for other range
    • Operating temperature range:  10~40°C (50~104°F), 15%~85% RH 
    • Storage temperature:  -20~50°C (-4~122°F), RH ≤85%
    • Transportation temperature:  Shall be less than 70°C, RH ≤95%
    • Response time (90%):  1 sec.
    • Display mode:  Oral
    • Scale selection:  °C / °F
    • Display type:  Large LCD
    • Memory:  25 sets
    • Disposable probe cover: Mold ring W/PE film cover
    • Temperature Awareness Signal:  Beep Sounds
    • Backlight:  Yes
    • Battery type:  CR2032 * 1 pcs
    Note: Subject to upgrade based on purchasing agreement.

     ► Feature
     
    smallest probe_709

    Smallest Probe

    detector-th709

    Probe Cover Detector

    last reading

    Last Reading

    storage box

    Storage Box


     
     ► Certificates


     
  •   This thermometer must only be used with RADIANT® probe covers .
    Donotreuse   Do not reuse : Always use a clean, undamaged and new probe cover. Be sure ear canal is clean.
     
    storage box_200x190
     Probe Cover
    fixer_200x190
     
    Probe Cover Fixer
    1) Place the probe cover on the probe cover fixer. Place adhesive side upward. 
    2) Insert the probe into the probe cover fixer until you feel a“click”. 
     

Technology Support

    • 1.How to open the battery cover to replace battery?+

      Please use the incisive tool, for example:Pen tip…And so on. Inserts on battery cover's safely vent, under the effort presses, simultaneously uses the thumb downward to shove open the battery cover, then replaces the battery.
       
      809battery-01  809battery-02   809battery-03
      (Battery installation picture take TH809 for example. For other models, please refer to the user's manual.)
    • 2.How do I have my ear thermometer repaired?+

      Please send the complete device to the nearest retailer for service.
    • 3.My temperature measured in the right ear is different from that measured in left ear?+

      The ear canal of both ears is not totally the same. Some people can get same temperature but most people could get 0.5 ~ 1.0°C different temperatures. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
    • 4.What is the standard for fever?+

      Different site in the body and different thermometers may get different temperatures.
      Recommended fever standards stated below:

       
      Site Fever Standard Measuring Time
      Oral 37.5 °C 1 min. half - 2 min.
      Forehead 37.5 °C Several seconds
      Ear 38.0 °C Several seconds
      Axillary 37.0 °C 3 min.
      Rectal 38.0 °C 1 min. - 1 min. half

      Source ► Centers for Disease Control , R.O.C.(Taiwan)

       