Infrared Ear Thermometer

TH816E

  • Probe Cover for Hygiene 
  • Probe Cover Detector
  • One Second Measurement
  • Temperature Awareness Signal
  • LED Backlight
  • 25 memories
  • °C/°F Switchable
  • TH816E
    Probe Cover
  • TH816E
    1 Second Measurement
  • TH816E
    Temperature Awareness Signal
  • TH816E
    Probe Cover Detector
  • TH816E
    LED Backlight

Introduction

    • Temperature measureme range:  34~42.2°C (93.2~108°F)
    • Accuracy:  ±0.2°C (0.4°F) within 35~42°C (95~107.6°F), ±0.3°C (0.5°F) for other range
    • Operating temperature range:  10~40°C (50~104°F), 15%~85% RH 
    • Storage temperature:  -20~50°C (-4~122°F), RH ≤85%
    • Transportation temperature:  Shall be less than 70°C, RH ≤95%
    • Response time (90%):  1 sec.
    • Display mode:  Oral
    • Scale selection:  °C / °F
    • Display type:  Large LCD
    • Memory:  25 sets
    • Disposable probe cover:  Mold ring W/PE film cover
    • Temperature Awareness Signal:  Beep Sounds
    • Battery type:  CR2032 * 1 pcs
    Note: Subject to upgrade based on purchasing agreement.

     ► Feature
     
    th816e_probe-cover3

    Probe Cover

    th816e_led-backlight

    LED Backlight

    th816e_detector

    Probe Cover Detector

    1sec

    One Second Measurement

     

     
     ► Certificates


     
  • Donotreuse  Do not reuse : Always use a clean, undamaged and new probe cover. Be sure ear canal is clean.
      For RADIANT® Infrared Ear Thermometer "THXX6 series". 
     
    feature-1
    Insert the probe into a new probe cover.
    feature-2
    Push the probe cover to the bottom of the probe until the  “Click” sound. This means the probe cover has been installed successfully.
     

Technology Support

    • 1.My temperature measured in the right ear is different from that measured in left ear?+

      The ear canal of both ears is not totally the same. Some people can get same temperature but most people could get 0.5 ~ 1.0°C different temperatures. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
    • 2.The measurement in air conditioning room is different from that in non- air conditioning room?+

      When ear thermometer is under rapid temperature change, we recommend user to place thermometer for 15 minutes to adapt to temperature and get the right temperature.
    • 3.What is the standard for fever?+

      Different site in the body and different thermometers may get different temperatures.
      Recommended fever standards stated below:

       
      Site Fever Standard Measuring Time
      Oral 37.5 °C 1 min. half - 2 min.
      Forehead 37.5 °C Several seconds
      Ear 38.0 °C Several seconds
      Axillary 37.0 °C 3 min.
      Rectal 38.0 °C 1 min. - 1 min. half

      Source ► Centers for Disease Control , R.O.C.(Taiwan)

       

    • 4.Does summer and winter ambient temperature affect the measurement?+

      RADIANT INNOVATION ear thermometer compares ambient temperature and makes compensation. The measurement between 10°C~40°C (50°F~104°F) is the same, but the human body changes a little in different season and different environment. For example, the body temperature becomes hotter after exercise and hot shower.