Infrared Ear Thermometer

TH859S

  • Probe Cover for Hygiene
  • Probe Cover Detector
  • One Second Measurement
  • Worldwide Smallest Probe (option)
  • Temperature Awareness Signal
  • 9 memories
  • °C/°F Switchable
  • TH859S
    Probe Cover
  • TH859S
    1 Second Measurement
  • TH859S
    Wordwide Smallest Probe
  • TH859S
    Probe Cover Ejector
  • TH859S
    Probe Cover Detector

Introduction

    • Temperature measureme range:  34~42.2°C (93.2~108°F)
    • Accuracy:  ±0.2°C (0.4°F) within 35~42°C (95~107.6°F), ±0.3°C (0.5°F) for other range
    • Operating temperature range:  10~40°C (50~104°F), 15%~85% RH 
    • Storage temperature:  -20~50°C (-4~122°F), RH ≤85%
    • Transportation temperature:  Shall be less than 70°C, RH ≤95%
    • Response time (90%):  1 sec.
    • Display mode:  Oral
    • Scale selection:  °C / °F
    • Display type:  Large LCD
    • Memory:  9 sets
    • Disposable probe cover: Mold ring W/PE film cover
    • Temperature Awareness Signal:  Beep Sounds
    • Backlight:  Option
    • Battery type:  CR2032 * 1 pcs
    Note: Subject to upgrade based on purchasing agreement.

     ► Feature
     
    smallest probe_th8

    Worldwide Smallest Probe
    (option)

    detector-th8

    Probe Cover Detector

    ejector-th8

    Probe Cover Ejector
    (option)

    1sec

    One Second
    Measurement

     


      ► Certificates
    Certificates
  •  
    軟耳套安裝_new
    For RADIANT® Infrared Ear Thermometer "THXX9 series". 

    Donotreuse Do not reuse : Always use a clean, undamaged and new probe cover. Be sure ear canal is clean. 

    (1) Attach the probe cover to the connection ring.
    (2) Align the center of probe cover with the center of probe.
    (3) Push the connection ring until the click sound. This means the probe cover has been firmed tightly.
     

     
    ► Probe Cover Loader (option)
     
    step1

    Fill with probe covers

    step2

    Pull the loader once to load a new probe cover

    step3

    The loader will automatically bounce back. A new probe cover will be on the fixer.

    step4

    Install a new probe cover

Technology Support

    • 1.My temperature measured in the right ear is different from that measured in left ear?+

      The ear canal of both ears is not totally the same. Some people can get same temperature but most people could get 0.5 ~ 1.0°C different temperatures. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
    • 2.The measurement in air conditioning room is different from that in non- air conditioning room?+

      When ear thermometer is under rapid temperature change, we recommend user to place thermometer for 15 minutes to adapt to temperature and get the right temperature.
    • 3.What is the standard for fever?+

      Different site in the body and different thermometers may get different temperatures.
      Recommended fever standards stated below:

       
      Site Fever Standard Measuring Time
      Oral 37.5 °C 1 min. half - 2 min.
      Forehead 37.5 °C Several seconds
      Ear 38.0 °C Several seconds
      Axillary 37.0 °C 3 min.
      Rectal 38.0 °C 1 min. - 1 min. half

      Source ► Centers for Disease Control , R.O.C.(Taiwan)

       

    • 4.Does ear thermometer need to maintain regularly?+

      Radiant_infrared_ear_thermometer_clean

      Ear thermometer is a health care product that needs maintenance, you could use soft cloth to wipe the  appearance. Never use benzene for cleaning and never submerge thermometer into water or any liquids. Probe lens is the most delicate part of thermometer, please use cotton swab with alcohol (70%) to wipe it.

      Follow the below instruction and video to clean the probe lens.
      ►Probe Lens Cleaning Video

      cleaning_e


       
      1. Before using the cotton swap with 70% alcohol to wipe the lens, slightly flip the cotton swab to cut down the spare alcohol.
      2. If there is no 70% alcohol, use alcohol prep pad to soak the cotton swab.

        Important:  Do not use sharp pointed object to wipe the lens.